 ^ [[https://​drive.google.com/​open?​id=1vHh7O8dokAw2sT8fcmCTQL5zGVdqBmqC|WT901C485]] |3.3-5V|RS485(Modbus) protocol| ​ XYZ\\ ±2、4、8、16 ​ |X Y Z |  X Y Z  |  X Y 0.05  |  yes  |  yes  |    |  200hz  | Static and dynamic| ​ ^ [[https://​drive.google.com/​open?​id=1vHh7O8dokAw2sT8fcmCTQL5zGVdqBmqC|WT901C485]] |3.3-5V|RS485(Modbus) protocol| ​ XYZ\\ ±2、4、8、16 ​ |X Y Z |  X Y Z  |  X Y 0.05  |  yes  |  yes  |    |  200hz  | Static and dynamic| ​
 ^ [[https://​drive.google.com/​open?​id=1fPKKoj5wMArZd201R_nXOc4iLNIMz_Rz|HWT901B]] |TTL(3.3-5V),​RS232/​RS485(9-36V)|TTL/​RS232/​RS485| ​ XYZ\\ ±2、4、8、16 ​ |X Y Z |  X Y Z  |  X Y 0.05  |  yes  |  yes  | yes   ​| ​ 200hz  | Static and dynamic| ^ [[https://​drive.google.com/​open?​id=1fPKKoj5wMArZd201R_nXOc4iLNIMz_Rz|HWT901B]] |TTL(3.3-5V),​RS232/​RS485(9-36V)|TTL/​RS232/​RS485| ​ XYZ\\ ±2、4、8、16 ​ |X Y Z |  X Y Z  |  X Y 0.05  |  yes  |  yes  | yes   ​| ​ 200hz  | Static and dynamic|
-^ [[https://​drive.google.com/​open?​id=1zADjnsW2WxLN_YGyvwtUvYK_n8X9e78w|WT901WIFI]]|3.3-5V|WiFi| ​ XYZ\\ ±2、4、8、16 ​ |X Y Z |  X Y Z  |  X Y  0.05  |  yes  |  yes  |    |  ​200hz  | Static and dynamic|+^ [[https://​drive.google.com/​open?​id=1zADjnsW2WxLN_YGyvwtUvYK_n8X9e78w|WT901WIFI]]|3.3-5V|WiFi| ​ XYZ\\ ±2、4、8、16 ​ |X Y Z |  X Y Z  |  X Y  0.05  |  yes  |  yes  |    |  ​20hz on PC ,30Hz on APP ,5 Hz on Server ​ | Static and dynamic|
 ^ [[https://​drive.google.com/​open?​id=1mOx3Pusab-TKJ7K9Pt5FnH3x-yOHj3JW|HWT905]]|TTL(3.3-5V),​RS232/​RS485(9-36V)|TTL/​RS232/​RS485| ​ XYZ\\ ±2、4、8、16 ​ |  X Y Z  |  X Y Z  |  X Y 0.05  |  yes  |  yes  |  yes  |  100hz  | Static and dynamic| ^ [[https://​drive.google.com/​open?​id=1mOx3Pusab-TKJ7K9Pt5FnH3x-yOHj3JW|HWT905]]|TTL(3.3-5V),​RS232/​RS485(9-36V)|TTL/​RS232/​RS485| ​ XYZ\\ ±2、4、8、16 ​ |  X Y Z  |  X Y Z  |  X Y 0.05  |  yes  |  yes  |  yes  |  100hz  | Static and dynamic|
 ^ [[https://​drive.google.com/​open?​id=1o-bcjaoml6dNeXbMDcYy7-0kfL0J1B3A|SINDT]]|TTL(3.3-5V),​RS232/​RS485(9-36V)|TTL/​RS232/​RS485| ​ XYZ\\ ±2、4、8、16 ​ |X Y Z |  X Y   ​| ​ X Y 0.05  |    |  yes  |    |  200hz  | Static and dynamic| ^ [[https://​drive.google.com/​open?​id=1o-bcjaoml6dNeXbMDcYy7-0kfL0J1B3A|SINDT]]|TTL(3.3-5V),​RS232/​RS485(9-36V)|TTL/​RS232/​RS485| ​ XYZ\\ ±2、4、8、16 ​ |X Y Z |  X Y   ​| ​ X Y 0.05  |    |  yes  |    |  200hz  | Static and dynamic|